"Always On Call, Always 100% Customer Satisfaction Guaranteed!"
GET A QUOTE!
PROPER ICE MACHINE CLEANING AND MAINTENANCE
Very few end users fully understand the importance of properly cleaning and sanitizing their ice machines, storage bins, and dispensers. Many don’t even view ice as a food
commodity. Yet the quality and safety of every beverage they serve as well as the longevity and power consumption of their equipment depend on proper maintenance of this equipment.
Adding to the problem is that some contractors and technicians may not realize the importance of how to properly perform this task and how to help customers maintain the quality of ice that is being consumed. Many rush through ice machine cleaning and sanitizing using untrained, entry-level personnel to minimize the cost to their customers. In reality, they are doing their customers a disservice by not being effective at eliminating bacterial growth and scale deposits.
Here are some tips that can help your company do a thorough job when cleaning this equipment and help ensure your customers’ food safety.
Ice Machine Water Filtration
Nothing is more important than the water going into the machine. Therefore, analyze the local water conditions to determine what kind of filtration is needed. Recent Legionnaires’ disease outbreaks as well as cryptosporidiosis and giardiasis traced back to ice machines have caused a change in philosophy of water filtration for equipment. Be aware that using carbon filters, which are typically used for taste and odor elimination, is not a good solution. ANSI/ASHRAE Standard 188-2015, “Legionellosis: Risk Management for Building Water Systems,” states that disinfectant should remain in the water supply. This means chlorine and chloramines should not be eliminated, and carbon taste and odor filters remove all such disinfectants. Particulates and parasitic cysts still need to be removed, and scale inhibitor needs to be added. Filters are available that will accomplish this — consult with your
local suppliers.
Clean Ice Machine Completely!
When cleaning an ice machine, disassemble, soak, and hand-clean as many components as possible. Remove all ice and clean and sanitize the storage bin, as well. Clean the underside of the machine, all drain lines, and the outside of the bin or dispenser. Sanitize completely using quaternary ammonia. Mix some in a spray bottle and spray all surfaces at the completion of your service and allow it to dry on its own. Do not rinse it off. This will help deter bacterial and biofilm growth. Any growth left in drains, bins, or dispense areas will cause regrowth at a much faster rate. Clean and flush completely.
Use Manufacture Approved Chemicals
Use only chemicals for scale removal that are approved by the manufacturer. Some materials and the plating of metal surfaces can be damaged by improper chemicals. Plastic pieces and hoses can be removed and cleaned with stronger chemicals, if necessary. Always use hot water when mixing chemicals, and always mix them to the suggested strength. Adding more cleaner will not help. Running cleaner through the machine longer doesn’t help either. After 20-30 minutes of cleaning, the pH level of the cleaner is back to neutral and it is no longer effective.
Mix up a new batch of cleaner and re-clean, as necessary. Never mix different cleaners together or add more to a mixed solution. Remember, as with all chemicals, follow the material safety data sheet (MSDS) guidelines for personal protective equipment, and be aware of how to treat exposure. Be prepared to properly clean up any accidental spills. Safety glasses or goggles and long chemical gloves are a must.
Ice Machine Cleaning Tools
Nylon brushes, toothbrushes, and mild abrasive pads can all be used. Avoid using anything that might scratch or mar any surfaces, because any place that is scratched or marred will allow scale and bacteria a place to grab onto and grow. For cleaning out hoses and crevices, specialty brushes can be obtained. One source is your local music store – the brushes used for cleaning out trombones and French horns can be used for cleaning out hoses and drain lines.
Another way of dislodging debris in drains is to adapt a hose fitting to ¼-inch poly tubing and putting about a 6-foot length of tubing down the drain line to flush it out. This works well on reach-in and walk-in refrigeration units, as well. Remember, you are not just trying to make sure these lines drain — you are ensuring they are flushed out completely in order to prevent regrowth.
Alternative Ice Machine Treatments
Ultraviolet lights, chlorine sachets, ozone water treatment, and other technologies are available both as OEM accessories and as aftermarket kits. These devices are designed to inhibit bacterial and biological film growth, though they’ll generally do nothing for scale buildup. Many manufacturers have developed special plastics that inhibit microbial growth, as well, so make sure any aftermarket devices will not void any warranties. In most cases with newer machines that have the antimicrobial plastics, it is not usually necessary to add anything beyond regular maintenance to keep machines clean. Exceptions are where airborne yeast is present, such as in bakeries, sandwich shops, and pizzerias. Also, be aware that any exposure to beer causes an increase in bacterial growth and increases the risk of contamination.
Flake and Nugget Ice Machines
Flake and nugget ice machines require a little special care. They will hold more mineral deposits because of their entire use of the water source (as opposed to cubers that only freeze pure water). When working with flake and nugget machines, be sure you pull the extrusion head, check the auger and evaporator surface, check all bearing tolerances, and make sure drive motor amperage is correct after cleaning.
Run an Ice Machine Production Check
Remember, the most important thing is to deliver quality ice to customers with no imperfections or contamination. After cleaning an ice machine, it’s a good idea to run a production test to ensure the machine is working properly. It’s also a good idea to take before-and-after pictures, as well.
To run a production test for a cuber, simply time, catch, and weigh a batch of ice and record the air temperature entering the condenser and the water temperature. Convert time to a decimal (for example, 14 minutes and 30 seconds would be 14.5) divide that into 1,440 (the number of minutes in a 24-hour period) and one will arrive at the number of cycles per day. Multiply that by the weight and that will give total production for a day. Compare this to the manufacturer’s published production for the ambient and water temperatures (see the sidebar, “Make Sure Ambient Air Reaches the Condenser.”)
For a nugget or flake ice machine, it is even easier. Catch ice for 15 minutes and weigh. Multiply by four and then again by 24 and that will total the 24-hour production that can then be compared to the manufacturer’s specifications for the given ambient and water temperatures.
After ensuring proper operation, a tech may need to coach the customer on proper ice management. Remind them not to waste ice. Explain to them to fill all drink stations and bar boxes at the end of the night and first thing in the morning and to rake the ice down afterwards to ensure the machine is running 24 hours a day. This will ensure maximum production, especially during high summer demand.
By making sure the proper water filtration is in place, cleaning the equipment properly and regularly (generally every six months), and educating customers on how to get the most out of their ice machines, a company can provide exceptional service and help eliminate one of the industry’s customers’ biggest headaches: running out of ice. In addition, a tech can ensure customers are receiving quality beverages, as well.
SIDEBAR: Tips from the Ice Machine Manufacturers
From Hoshizaki America Inc.’s service department: “All ice machines require at least an annual cleaning and sanitizing — more often if conditions require it. Proper cleaning is a two-step process that should be done with a compatible cleaner and sanitizer, per the manufacturer’s specifications.”
The most important maintenance step for ice machines is making sure the periodic cleaning gets done regularly. “If end users don’t maintain their machines, it can lead to downtime,” he said. “The most common symptoms described to the Follett help desk are nearly always solved by asking that the machine be cleaned. Contractors and technicians can help prevent problems with these machines by impressing upon end users the need for and importance of regular maintenance.”
Jonathan Bailey, factory school instructor, Manitowoc Ice, shared two handy tips.
“If you find it difficult to pour ice machine cleaner or sanitizer into the water trough, fill an empty squeeze ketchup bottle and squirt it in,” Bailey said. “Remember to always wear safety glasses when dealing with chemicals.”
Bailey also said never to mix ice machine cleaner and sanitizer together, as this will render them ineffective.
Lester L. Tatum, national field service manager, Scotsman Ice Systems, had tips for making the correct diagnosis when dealing with misshapen ice cubes.
“Misshapen cubes or small or oversized cubes can be caused by many factors,” Tatum said. “For example, a dirty evaporator grid can cause release problems and misformed cubes. This could lead the service technician to misdiagnose and make unnecessary bridge adjustments when deliming may have corrected the problem.”
Tatum offered a six-point plan for dealing with malformed cubes, noting that an ice machine needing deliming will not provide good diagnostics:
1. Run a few cycles and check sequence of operation;
2. Check total cycle time (freeze and harvest) and compare it to the manufacturer’s time table. Check if the unit ran max freeze or max harvest;
3. Check out the components in freeze and harvest. Are they powered up per the sequence of operation?;
4. Check the ice pattern on the evaporator and how ice is released off the grid;
5. Check condenser inlet air temp and inlet potable water temp. Most manufacturer’s incoming water limitations are between minimum 40° and 100°F, and these temperatures will factor in to determine the length of cycle times; and
6. Gauge up only when all mechanicals have checked out, and the root cause(s) of failure point toward a refrigeration problem.
SIDEBAR: Make Sure Ambient Air Reaches the Condenser
Keep in mind that self-contained ice machines are often installed without enough clearance to allow ambient temperature air to enter the condenser. An increase of 10°F on ambient temperature can cause a 10 percent loss in production and it can get worse in a hot environment. In Texas, temperatures have measured as high as 125° entering-air temperature and 90° degree water temperatures on remote ice machines during the summer. Educate customers that a 1,400-pound ice machine only makes 1,400 pounds a day at the standard of 70° ambient and 50° water temperatures.
Email us or give us a Call if You Prefer to Let us Help you with any of your commercial refrigeration needs.